Heating needs vary with outside temperatures and flow requirements for a family home vary between 0.5 and 2.0 m³/h. The flow rate is dependent upon the water temperature as well as the type of insulation and size of the building. The following table shows the typical flow requirements during a year.

miniwattUKChart

Operational periods of a circulator:

• For three quarters of the year a circulator works at less than half of its capacity.
• For 18 days a circulator works at 100%.
• For 6 months a circulator works at 25%.n and size of the building. The following table shows the typical flow requirements during a year.

miniwattUKChart1

Miniwatt energy consumption:

Flow % Flow m3/h Operation % Operation Hours Power P1 W Energy
kWh/year
100 2 5 438 34,5 15,1
80 1,6 15 1314 33,5 44
60 1,2 35 3066 32,5 99,6
25 0,5 45 3942 29 114,3
Yearly Total 100 8760   273


The energy consumption for a standard domestic circulator is usually between 500 and 600 kWh/ per year, giving a saving of approximately € 375 / £ 200 calculated over a 10-year period.

 